Draw Wire Sensors and Encoders

Magnetic measurement; high resolution; robust stainless steel wire; small aluminum body; resistant to shocks and vibrations

 Stroke (measuring) Lengths Resolution Output Type Protection  Linearity Datasheet
0...300 mm  6µm CANopen IP67 ±%0,25 FS

 Potentiometric measurement; robust stainless steel wire; anodised aluminum and small body; resistant to shocks and vibrations

Stroke (measuring) Lengths Output Protection Linearity Datasheet

Different measuring lengths between 0…200 mm and 0…1250 mm

Potentiometric, 4-20 mA Current,  0-10 V DC Voltage IP 53 (Optional IP 67) ±0,25% FS

 Potentiometric measurement; robust stainless steel wire; anodised aluminum body; resistant to shocks and vibrations

Stroke (measuring) Lengths Output Protection Linearity Datasheet
Different measuring lengths between 0…1000 mm and 0…5000 mm Potentiometric, 4-20 mA Current,  0-10 V DC Voltage IP 53 (Optional IP 67) ±0,25% FS

 

Potentiometric measurement; robust stainless steel wire; suitable for long distance measurements; anodised aluminum body; resistant to shocks and vibrations

Stroke (measuring) Lengths Output Protection Linearity Datasheet
Different measuring lengths between 0…5100 mm and 0…11000 mm Potentiometric, 4-20 mA Current,  0-10 V DC Voltage IP 53 (Optional IP 67) ±0,25% FS

Potentiometric measurement; robust stainless steel wire; suitable for long distance measurements; anodised aluminum body suitable for outdoor use; resistant to shocks and vibrations

Stroke (measuring) Length Output  Protection   Linearity Datasheet
Different measuring lengths between 0…1000 mm and 0…4200 mm Potentiometric, 4-20 mA Current,  0-10 V DC Voltage or CANopen IP 67 ±0,1% FS

Potentiometric measurement; robust stainless steel wire; suitable for long distance measurements; anodised aluminum body suitable for outdoor use; resistant to shocks and vibrations 

Stroke (measuring) Length Output  Protection Linearity  Datasheet
Different measuring lengths between 0…4000 mm and 0…8000 mm Potentiometric, 4-20 mA Current,  0-10 V DC Voltage or CANopen IP 67 ±0,1% FS

Potentiometric measurement; robust stainless steel wire; suitable for long distance measurements; anodised aluminum body suitable for outdoor use; resistant to shocks and vibrations

Stroke (measuring) Length Output  Protection Linearity Datasheet
Different measuring lengths between 0…5000 mm and 0…12000 mm Potentiometric, 4-20 mA Current,  0-10 V DC Voltage or CANopen IP 67 ±0,1% FS

Potentiometric measurement; robust stainless steel wire; suitable for long distance measurements; anodised aluminum body suitable for outdoor use; resistant to shocks and vibrations

Stroke (measuring) Length Output  Protection Linearity Datasheet
Different measuring lengths between 0…13000 mm and 0…22000 mm Potentiometric, 4-20 mA Current,  0-10 V DC Voltage or CANopen IP 65 or IP 67 ±%0,5 FS

Potentiometric measurement; robust stainless steel wire; suitable for long distance measurements; anodised aluminum body suitable for outdoor use; resistant to shocks and vibrations

Stroke (measuring) Lengths Output Protection Linearity Datasheet
Different measuring lengths between 0…2000 mm and 0…5100 mm  Potentiometric, 4-20 mA current,   0-10 V DC Voltage or CANopen  IP 67 ±0,25% FS

Potentiometric measurement; robust stainless steel wire; suitable for long distance measurements; anodised aluminum body suitable for outdoor use; resistant to shocks and vibrations

Stroke (measuring) Lengths Output Protection Linearity Datasheet
Different measuring lengths between 0…6000 mm and 0…14500 mm Potentiometric, 4-20 mA Current,  0-10 V DC Voltage or CANopen  IP 67 ±0,25% FS

 

Incremental measurement; robust stainless steel wire; anodised aluminium body; resistant to shocks and vibrations

Stroke (measuring) Lengths Output Protection Resolution  Datasheet
Different measuring lengths between 0…300 mm and 0…1250 mm   Incremental IP 53 (optional IP 67) 0.1 mm/pulse(standard), 0.2 mm/pulse, 0.05 mm/pulse

Incremental measurement; robust stainless steel wire; anodised aluminum body; resistant to shocks and vibrations

Measuring Range Output Protection Resolution  Datasheet
Different measuring lengths between 0…1000 mm and 0…5000 mm Incremental IP 53 (optional IP 67) 0.2 mm/pulse

Incremental measurement; robust stainless steel wire; anodised aluminum and small body; resistant to shocks and vibrations 

Stroke (measuring) Lengths Output Protection Resolution Datasheet
Different measuring lengths between 0…5000 mm and 0…11000 mm Incremental IP 53 (optional IP 67) 0.3 mm/pulse

Incremental measurement; robust stainless steel wire; anodised aluminum and small body; resistant to shocks and vibrations

Stroke (measuring) Lengths Output Protection Resolution  Datasheet
Different measuring lengths between 0…1000 mm and 0…4200 mm Incremental IP 67 0.05 mm/pulse, 0.1 mm/pulse or 0.2 mm/pulse

Incremental measurement; robust stainless steel wire; anodised aluminum and small body; resistant to shocks and vibrations

Stroke (measuring) Lengths Output Protection Resolution  Datasheet
Different measuring lengths between 0…4000 mm and 0…8000 mm Incremental IP67 0.05 mm/pulse, 0.1 mm/pulse or 0.2 mm/pulse

Incremental measurement; robust stainless steel wire; anodised aluminum and small body; resistant to shocks and vibrations

Stroke (measuring) Lengths Output Protection Resolution  Datasheet
Different measuring lengths between 0…5000 mm and 0…12000 mm Incremental IP 67  0.3 mm/pulse

Draw wire sensor for measuring linear movements; robust measuring wire made of stainless steel; resistant to environmental factors; easy mounting

Stroke Values Output Protection Linearity  Datasheet
3000, 4000, 5000, 6000, 8000, 10000 or 12000 mm Analog 4-20 mA or 0-10 VDC IP 54 ±0,25%

Draw wire sensor for measuring linear movements; robust measuring wire made of stainless steel; resistant to environmental factors; easy mounting

Stroke Values Output Protection Linearity Datasheet
2000 mm Analog 4-20 mA or 0-10 VDC IP 54 ±0,25%

Draw wire sensor for measuring linear movements; robust measuring wire made of stainless steel; resistant to environmental factors; easy mounting 

Stroke Values Output Protection Linearity Datasheet
1000 or 2000 mm Analog 4-20 mA or 0-10 VDC IP 54 ±0,25%

Draw wire sensor for measuring linear movements; robust measuring wire made of stainless steel; resistant to environmental factors; easy mounting

Stroke Values Output Protection Linearity Datasheet
50, 100, 200, 300, 500, 700 or 900 mm
Analog 4-20 mA or 0-10 VDC IP 54 ±0,25%

Draw wire encoder with optical principle for incremental measurement of linear movements; robust measuring wire made of stainless steel; resistant to environmental factors; easy mounting

Stroke Values Output Protection Resolution Datasheet
4000, 5000, 6000, 8000, 1000 or 12000 mm 
 Push-Pull, Line Driver 5 V DC or 10-30 V DC
IP 54 100 µm 

Draw wire encoder with optical principle for incremental measurement of linear movements; robust measuring wire made of stainless steel; resistant to environmental factors; easy mounting

Stroke Values Output Protection Resolution Datasheet
1000, 2000 and 3000 mm 
 Push-Pull, Line Driver 5 V DC or 10-30 V DC
IP 54 100 µm 

Draw wire encoder with optical principle for incremental measurement of linear movements; robust measuring wire made of stainless steel; resistant to environmental factors; easy mounting 

Stroke Values Output Protection Resolution Datasheet
500, 700 and 900 mm  Push-Pull, Line Driver 5 V DC or 10-30 V DC IP 54
EF: 100 µm
EFM: 10 µm 

Service & Support

Contact

Aydınlı-KOSB Mahallesi, Kimyacılar OSB, Melek Aras Bulvarı No:67 34953 Tuzla / İstanbul, TURKEY

Tel :      +90 (216) 399 44 04

Fax :     +90 (216) 399 44 02

Mail :     [email protected]